Home / Schemes/Projects / Design Tool-6 – Distribution & Gravity Main Design, Pipe Economiser and Booster-Pump Optimiser

Design Tool-6 – Distribution & Gravity Main Design, Pipe Economiser and Booster-Pump Optimiser Last Updated : Mon, 16 Nov 2026

JSV Design Tool-6 – Distribution / Gravity Main Design and Booster Optimiser – Himachal Pradesh

Design Tool-6 – Distribution & Gravity Main Design, Pipe Economiser and Booster-Pump Optimiser – Jal Shakti Vibhag (JSV), Himachal Pradesh

Feed the RD / RL profile and the delivery points of a gravity, pumped or boosted distribution main (intermittent or 24×7, with a two-end-fed loop option). The tool economises the diameter, material, grade and wall thickness section by section, places booster stations and break-pressure tanks, and checks hydraulic grade, pressure, velocity, surge, valves, meters and leak-detection.

I1. Longitudinal section (RD, RL) and delivery points
I2. Supply mode, demand, source and hydraulics
I3. Pipe materials and classes available
I4. Economic variables and capital costs
I5. Constraints, boosters, pressure management, surge, valves, meters and leak detection
I6. Junction tapping points and house connections (up to 100 junctions of about 100 houses each)
I6. Junctions, branch mains and house connections (up to 100 junctions)
Preliminary design aid for departmental use. All defaults (demand norms, peak factors, costs, tariff, efficiencies, stress limits, DI catalogue ratings, surge allowance, valve, meter and logger rules) are editable assumptions, not departmental orders; check pipe ratings against the manufacturer's current catalogue and the applicable BIS / ISO / CPHEEO / JJM provisions. The network is analysed as a single trunk (with one withdrawal at each delivery node, or fed from both ends in loop mode); branched or multi-ring networks, valve operation and extended-period behaviour must be verified in EPANET / WaterGEMS before finalising. Surge results are a screening (Joukowsky) check only. Pump efficiency and NPSH figures are indicative; select pumps from the manufacturer's curves.